F.R.P. (Fiber Reinforced Plastics) equipment manufacturing is mainly based on the ASME RTP-1 design regulations or the domestic CNS11656 F.R.P. chemical tank (filament winding) regulations. |
Operating condition | Important design considerations | |
Equipment endurance | Chemical resistance | Choose appropriate material to design and manufacture the product based on the nature and concentration of the content. |
Weather resistance | Provide adequate UV-resistance or acid rain resistance as per the clients’ request. | |
Equipment strength | Operating pressure | Conduct structural strength design in accordance with ASME RTP-1/CNS11656 regulations. |
Liquid specific gravity | ||
Geographical factors (wind/earthquake etc.) | ||
External factors (base of the agitator etc.) | ||
Structural factor | Storage tanks are usually available in vertical/horizontal/tall configurations, and independent calculations are required for each to determine if its structural strength conforms to the safety coefficient. |